AIRWORTHINESS DIRECTIVE
CAA-AD-018/2001
Date of issue:
February 20, 2001
AIRCRAFT - ELECTRICAL CIRCUIT (ATA 92, 24, 29) –
MODIFICATION
Applicability: Model ATR 72-101/-201/-102/-202/-211 and
–212 on which modification 3719 has not been embodied.
Effective date: Upon receipt
Compliance: Required as indicated in DGAC AD 2001-056-055(B).
Remarks: The compliance of this AD must be recorded in Aircraft Logbook, where applicable the requirements of this AD must be integrated into Aircraft Technical Documentation. Address inquiries concerning this AD to: Civil Aviation Authority, Airworthiness Division, Ruzyne Airport, 160 08 Prague 6, Czech Republic, tel: 420 2 33320922, fax: 420 2 20562270.
Ing. Pavel MATOUŠEK
Director of
Airworthiness Division
CAA CZ
DGAC AD ref. No.: 2001-056-055(B)
EADS ATR
ATR 72 aircraft
Electrical circuit – Wiring conduit between
frame 28 and 28 A (ATA 92, 24, 29)
1. APPLICABILITY:
Model ATR 72-101/-201/-102/-202/-211 and
–212 on which modification 3719 has not been embodied.
2. REASONS:
The issuance of this Airworthiness Directive
(AD) is prompted by a recent event where, during taxi out, an ATR 72-202
experienced an elevator pitch disconnect followed by a loss of the green system
hydraulic pump and by a fire initiation.
Investigations revealed that the power
supply cables of the green system hydraulic pump chafed on the right hand
elevator control cable, between frames 28 and 28 A. This chafing led to a
short-circuit which caused the elevator control cable to snap and the hydraulic
pump power supply circuit breaker to trip. The heat generated started a small
fire which extinguished itself.
It has been determined that the
electrical short-circuit was caused by the installation of an oversized clamp
(diameter 20 mm) on the power supply cables loom (diameter 16 mm) of the green
system hydraulic pump, which gave the cables freedom to move.
Under such conditions, this clamp doesn´t
allow to correctly secure wiring conduit 2P in the forward area where the cable
loom changes direction.
The following corrective actions mandated
by this AD are intended to warrant a securely retain of the loom 2P containing
the green system hydraulic pump power supply wiring.
3. ACTION:
The following measures are rendered
mandatory on the effective date of this AD and have to be accomplished at the
first opportunity, and at the latest before March 02, 2001.
At frame 28, remove the oversized clamp
retaining the green circuit hydraulic pump power supply cable loom 2P and
install, instead of, a clamp diameter 16 mm in respecting its new fitting orientation
according to instructions given in Service Bulletin ATR 72-92-1004 (Mod. 8287)
or any further approved revision.
REF.: Service Bulletin ATR 72-92-1004 original issue dated
January 26, 2001
Any further approved revision of this SB is acceptable.
EFFECTIVE DATA: Upon receipt from FEBRUARY 07, 2001